Herunterladen Diese Seite drucken

Sio 1; Sio 2; Ptz Control; Ptz Interval - Sony PMS-500P Bedienungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

SIO PIO CONTROL Menu
PARITY BIT: Select the parity bit (NONE (none),
ODD (odd) or EVEN (even)).
STOP BIT: Select the stop bit (1 or 2).

SIO 1

You can set the TABLET port in this screen.
S I O 1
P R O T O C O L : R S - 2 3 2 C
B A U D R A T E : 9 6 0 0
C H A R A C T E R B I T : 8
P A R I T Y B I T : N O N E
S T O P B I T : 1
F L O W C O N T R O L : N O N E
< C A N C E L > < O K >
PROTOCOL: Select an interface (RS-232C, RS-
422A, CSP5000 or COMPUTER).
BAUD RATE: Select a baud rate (1200, 2400, 4800,
9600, 19200 or 38400).
CHARACTER BIT: Select the number of character
bits (7 or 8).
PARITY BIT: Select the parity bit (NONE, ODD or
EVEN).
STOP BIT: Select the stop bit (1, 1.5 or 2).
FLOW CONTROL: Select the flow control (NONE,
RTS/CTS or Xon/Xoff).

SIO 2

You can set the USER DATA port in this screen.
S I O 2
P R O T O C O L : R S - 2 3 2 C
B A U D R A T E : 9 6 0 0
C H A R A C T E R B I T : 8
P A R I T Y B I T : N O N E
S T O P B I T : 1
F L O W C O N T R O L : N O N E
< C A N C E L > < O K >
PROTOCOL: Select an interface (RS-232C, YS-
S100, RS485 or COMPUTER).
BAUD RATE: Select a baud rate (1200, 2400, 4800,
9600, 19200 or 38400).
CHARACTER BIT: Select the number of character
bits (7 or 8).
PARITY BIT: Select the parity bit (NONE, ODD or
EVEN).
2-14
(GB)
Chapter 2 Setup Using the SETTING Menu
STOP BIT: Select the stop bit (1, 1.5 or 2).
FLOW CONTROL: Select the flow control (NONE,
RTS/CTS or Xon/Xoff).

PTZ CONTROL

Select the CAMERA CONTROL port I/O (Input or
Output).
Note
When you select the CAMERA CONTROL port I/O
(Input/Output), you have to change the DIP switch
setting.
For details on DIP switch setting, consult your nearest
dealer.

PTZ INTERVAL

Select the Pan/Tilt/Zoom operation interval (20msec,
50msec, 100msec, 200msec or 500msec).

SIO PREFERENCE

You can set the SIO preference in this screen. This
screen is password-protected to prevent accidental
modifications. The password is "SERVICE".
Note
This menu is only for service personnel and the system
integrator.
S I O P R E F E R E N C E
S I O S C A N
: [ 6. . .]
D A T A C O U N T
: [ 8. . .]
T R I G G E R C O U N T : [ 2. . .]
0 1 2 3 4 5 6 7 8 9 BS
R A T E R E Q U E S T : 4 8 0 0
< C A N C E L > < O K >

Werbung