10.3.6.1 Selecting
Fig. 51: Configuration / Autostart - Selecting
- Autostart ist inaktiv (Default setting).
When the mains voltage is connected, the pump always enters the "OFF"
("Standby" in V 4.0) operating state.
3 autostart is active.
When the mains voltage is connected, the pump starts functioning in the configured
operation state.
10.3.7

Configuration / Metering lock

If the metering lock is enabled, the pump only functions if an external enable contact is
connected to plug II (or at plug VII or plug VIII, if a dongle box is used) between PIN 3+ 4
and an external enable contact is connected
(electrical connection
on page 41 and
Ä Chapter 8.2.4.3 'Installing the metering lock' on page 57).
The selected operating mode does not affect the use of the metering lock.
Ä Chapter 7.2.3.3 'Installing the control via the metering lock'
Ä Chapter 8.2.3.2 'Installing the metering lock' on page 54 and