10.3.13.4 Metering monitoring / Deviation (only at E60
A tolerance in % is set under "deviation".
The actual incoming pulse rate recorded by the oval gear meter within the pump interval
to be monitored
Ä Chapter 10.3.13.3 'Metering monitoring / Strokes' on page 84) is compared with the
(
target pulse rate defined during calibration.
If this comparison results in a deviation that is greater than the % value configured under
"deviation", a "metering monitoring alarm" is triggered.
NOTICE!
This function can only be selected if a dongle box is connected and
configuration/oval gear meter
Ä Chapter 10.3.11 'Configuration / Oval gear meter (only E60
(
OGM
Fig. 62: Metering monitoring / Deviation (only at E60
Setting range: 0-100%
Default setting = 20 %.
PLUS
)' on page 80) has been activated.
PLUS
& OGM bzw. OGM
PLUS
& OGM or OGM
PLUS
)
85
Menu description
PLUS
)
PLUS
&
417101442 Rev. 12-02.2019