4.2

Electronic functions

The pump is operated using four keys.
Ä Chapter 9.1 'Key functions' on page 58).
(Fig. 5) (
The operating indicator is shown on a graphical display (Fig. 5).
4.2.1

Operation modes

The pump may be used in three different operation modes:
INTERNAL
Manual metering function (factory setting)
EXTERNAL pulse control
EXTERNAL standard signal control (mA)
The Configuration menu item can also be used to set batch metering (a specific quantity is
metered on each start pulse).
4.3

Additional electronic functions on the EMP KKS E60

n
Oval gear meter connection / Oval gear meter evaluation
n
Metering regulation with a oval gear meter, type OGM
n
Automatic calibration is possible thanks to the oval gear meter, type OGM
n
Splitting of the metering lock/pulse/metering monitoring/oval gear meter inputs into
multiple connections to simplify the external connections.
Functional description
+
PLUS
27
PLUS
417101442 Rev. 12-02.2019