Technical Specifications
14.5.3
Connector III
Fig. 93: Connector III
output
empty/reserve/ fault
report
stroke signal
417101442 Rev. 12-02.2019
allocation external circuit
1 (brown)
+
external current
2 (white)
3 (blue)
external current
+
Note: Observe the polarity of
the connected signal!
4 (black)
126
declaration of value
max. external voltage 230 VAC/DC, max.
3 A
with reserve report:
contact approx. 500 ms closed
contact approx. 500 ms opened
max. external voltage 24 V DC, max 0,3
A
when stationary: Contact open
at 50 Hz mains power:
at 100 % run:
contact approx. 310 ms closed
contact approx. 180 ms opened
at 50 % run:
contact approx. 310 ms closed
contact approx. 660 ms opened
at 60 Hz mains power:
at 100 % run:
contact approx. 260 ms closed
contact approx. 150 ms opened
at 50 % run:
contact approx. 260 ms closed
contact approx. 550 ms opened