Check Hydraulic Oil Level - Jungheinrich EFG-DH ac 10 Betriebsanleitung

Elektro-fahrersitzgabelstapler
Vorschau ausblenden Andere Handbücher für EFG-DH ac 10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.3

Check hydraulic oil level

f
The load lifting device must be completely lowered.
–– Prepare truck for maintenance and
service operations (see section 6.1).
–– Unscrew air cleaner with level plunger
(3).
–– Visual check of hydraulic oil level on
the level plunge
A
The reading of the hydraulic oil level
must be at the upper mark (max.) when
the tank is sufficiently filled.
–– If required, top up with hydraulic oil un-
til the prescribed filling level is reached
(20 mm at the dipstick (3) correspond
to approx. 1 l hydraulic oil) (see section 5.1).
m
Do not fill hydraulic tank higher than the upper mark. This can cause disturbances and
damage of the system.
Changed consumption type materials must be disposed of in accordance with the ap-
plicable environmental protection regulations.
3
max.
min.
F 9