6
Closing battery cover
With Multi-Pilot (o):
– Push the control valve hood beyond
the locking point until the hood is auto-
matically closed by spring force.
With Solo-Pilot (t):
– After closing the battery cover, swivel
control valve cover to the back until it
engages.
7
Battery discharge indicator, battery discharge monitor, operating hour meter
Battery discharge indicator: The loading status of the battery (10) is indicated in
steps of 10% on the information and service indicator (100% = battery capacity 100%,
display 0% = battery capacity 20%).
m
The manufacturer setting of the bat-
tery discharge indicator / discharge
monitor is standard batteries.
It is required to recharge the bat-
tery,
if
the
amounts to 20% for standard bat-
teries or 40% for maintenance-free
batteries.
Battery discharge monitor: If the
residual capacity falls below the
specified minimum value, the lifting
function is switched off. A corre-
sponding message is displayed in
the information and service indica-
tor.
A
The lifting function will only then be released, if the connected battery is reloaded by
min. 40%.
Operating hours counter: The operating hours (11) are indicated next to the battery
discharge state. The operating hours counter indicates the overall times of driving
and lifting movements (below "Eff").
D 6
residual
capacity
11
10