3.6. Type key

Example: Wilo-EMU FA 10.82E + T 20.1-4/22KEx
Hydraulics definition
FA
Sewage series
Nominal diameter of pressure connection e.g.:
10
DN 100
82
Internal performance coefficient
Impeller shape
W = Vortex impeller
WR = Vortex impeller with mechanical stirring
apparatus
E = Single-channel impeller
E
Z = Two-channel impeller
D = Three-channel impeller
V = Four-channel impeller
T = SOLID impeller, closed
G = SOLID impeller, half open
Motor definition
T
Dry motor
20
Size
1
Internal code figure
4
Number of poles
22
Package length in cm
K
Sealing variant
Ex
Ex-rated motor

3.7. Technical data

Refer to the following documents for the com-
plete technical data:
• Catalogue sheet (for standard articles)
• Order confirmation (for configured articles)
• Attached data sheet (for configured articles)
3.7.1. Rating plate
The most important data can be found on the
rating plate.
Abbreviations on rating plate
P type
Hydraulics type
M type
Motor type
S/N
Serial number
Q
Volume flow
H
Delivery head
n
Speed
TPF
Max. fluid temperature
max
IP
Protection class
I
Rated current
I
Starting current
ST
P2
Nominal power P
F
Frequency
Cos φ
Cos phi
SF
Service factor
I
Rated current with service factor
SF
52
2
IM
Impeller diameter
Ø
OT
Immersed operating mode
S
OT
Non-immersed operating mode
E
MFY
Year of manufacture

3.8. Scope of delivery

Standard product
• Pump with 10 m cable and bare cable end
• Installation and operating instructions
Freely configured products
• Pump with cable length per customer request
• Cable version (depends on type)
• With bare cable end
• With plug
• With float switch and bare cable end
• With float switch and plug
• Mounted accessories, e.g. sealing chamber con-
trol, pump support foot, etc.
• Installation and operating instructions

3.9. Accessories

• Suspension unit
• Pump support foot
• External pencil electrode for sealing chamber
control
• Level control devices
• Versions in cast stainless steel or Abrasit and with
Ceram coating for aggressive and abrasive fluids
• Thermal motor monitoring with PTC sensors
• Various monitoring devices
• Fixing accessories and chains
• Switchgear, relays and plugs

4. Transport and storage

4.1. Delivery

On delivery, check immediately that the ship-
ment is complete and undamaged. If any parts
are damaged or missing, the transport company
or the manufacturer must be notified on the day
of delivery. Claims made after this date cannot be
recognised. Damage to parts must be noted on
the freight documentation.

4.2. Transport

Only the designated and approved sling gear,
transport and lifting equipment are to be used for
transportation. These must have sufficient load-
bearing capacity to ensure that the pump can be
transported safely. If chains are used they must
be secured against slipping.
The personnel must be qualified for the tasks and
must follow all applicable national safety regula-
tions during the work.
The pump is delivered by the manufacturer or
shipping agency in suitable packaging. This nor-
mally precludes the possibility of damage occur-
ring during transport and storage. The packaging
TRANSPORT AND STORAGE