If the values need to be changed, press the „Start/Enter" button. The discharge current blinks.
•
Change the discharge current using the buttons „+>" and „
The voltage/cell number then begins to flash.
•
Change the voltage/cell number using the buttons „+>" and „
•
You should be aware while doing this that the voltage only changes with the number of cells (e.g. one cell = 2.0V,
two cells 4.0V etc.) Confirm the setting by pressing the „Start/Enter" button.
+
The charger sets the final discharge voltage automatically for safety reasons.
•
To begin the discharge process, keep the „Start/Enter" button pressed (approx. 3 seconds).
•
If the settings are wrong, or if the charger detects a problem, an audio signal is emitted and the appropriate infor-
mation is shown on the display.
You can stop the audio signal by pressing the „Batt Type/Stop" button. You then return to the previous configura-
tion menu.
•
If you press the button „Start/Enter" during the discharge process, the discharge current can be changed (see
above).
•
Once the discharge process has been completed, an audio signal is emitted.
•
If you wish to terminate the discharge process beforehand, press the „BattType/Stop" button.
14. saVIng aCCuMulator data
The charger has altogether 5 memory slots in which you can save accumulator data/settings.
•
In the main menu, select the function „SAVE DATA" with the button „Batt Type/Stop".
", confirm the value using the „Start/Enter" button.
-
<
".
-
<