Briefly press the button „Start/Enter". The time then begins to flash.
With the buttons „+>" or „<-", you can select the time (1 to 60 min).
Save the setting with the button „Start/Enter"; the time stops blinking.
With the „+>" button, you access the next setting (or with the button „
menu with the button „Batt Type/Stop".
-
+
Start
Enter
However, do not set the time too short, otherwise the accumulator will not be fully charged.
Calculate the time for the safety timer as follows:
accumulator capacity
3300mAh
2000mAh
1000mAh
With factor 11.9, the accumulator is charged with 140% capacity before the safety timer kicks in.
100
The accumulator may become quite hot using the cycle program
(automatic charge/discharge cycles in sequence). Set a break
time here to allow the accumulator to cool off sufficiently.
-
+
As soon as a charge process starts, the internal timer starts as
well. If the charger cannot detect whether the accumulator is
fully charged for whatever reason (e.g. with delta-U detection),
the charge process is terminated automatically after a set time if
the safety timer is set to ON. This protects the accumulator from
-
+
overloading.
Charge current

timer time

3.0A
3300 / 3.0 = 1100 / 11.9 = 92 minutes
2.0A
2000 / 2.0 = 1000 / 11.9 = 84 minutes
1.2A
1000 / 1.2 = 833 / 11.9 = 70 minutes