Herunterladen Inhalt Inhalt Diese Seite drucken

VOLTCRAFT VC-1506 Bedienungsanleitung Seite 110

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Input voltage monitoring system (to protect against deep discharge)
Charging current limitation to protect NiMH batteries with low input resistance and low capacity
Temperature limitation system to protect batteries against overheating during charging. For this purpose, the tem-
perature sensor has to be connected and have contact with the battery.
Limitation of operating period. When the period selected lapses, this switches the battery charger off from each
process (charging, discharging, cyclical charging/discharging).
Adjustable capacity limit (to protect against overcharging the battery connected)
Adjustable charging period (to protect against overcharging the battery connected)
Max. power of the electronics for charging current 50 W (select lower charging current depending on the number
of cells)
b) Maximum charge/discharge currents when the battery charger is connected to 1-V input voltage
(automatic charge/discharge current detection system)
Battery type
number of cells
niCd/niMh
110
nominal voltage (V)
1
1,2
2
2,4
3
3,6
4
4,8
5
6,0
6
7,2
7
8,4
8
9,6
9
10,8
10
12,0
11
13,2
12
14,4
13
15,6
14
16,8
15
18,0
Charge current (a)
5,0
5,0
5,0
5,0
5,0
5,0
5,0
5,0
4,6
4,2
3,8
3,5
3,2
3,0
2,8
discharge current (a)
1,0
1,0
1,0
1,0
0,8
0,7
0,6
0,5
0,5
0,4
0,4
0,3
0,3
0,3
0.3