If the discharge current and the discharge voltage need to be set, press the „Start/Enter" button. The discharge
current blinks.
Change the discharge current using the buttons „+>" and „
You can set a value between 0.1A and 1.0A.
Afterwards, the final discharge voltage blinks, which is also set with the buttons „+>" and „<-". Voltage values
between 0.1V and 25.0V are possible.
When setting the voltage value, make sure that the cell voltage for NiMH may not be below 1.0V, with NiCd not
below 0.85V.
Otherwise the accumulator may be damaged!
To begin the discharge process, keep the „Start/Enter" button pressed (approx. 3 seconds).
Now the display shows different information just like during the charge process (discharge time, discharge capa-
city, discharge current and current accumulator voltage).
If you press the button „Start/Enter" during the discharge process, the discharge current can be changed (see
above).
If the settings are wrong, or if the charger detects a problem, an audio signal is emitted and the appropriate infor-
mation is shown on the display.
You can stop the audio signal by pressing the „Batt Type/Stop" button. You then return to the previous configura-
tion menu.
Once the discharge process has been completed, an audio signal is emitted.
If you wish to terminate the discharge process beforehand, press the „Batt Type/Stop" button.
c) Cycle program („CyCle")
To test or refresh accumulators, you can perform up to 5 cycles in sequence. The two possible combinations are
„Charge/Discharge" („CHG>DCHG") and „Discharge/Charge" („DCHG>CHG").
In the basic settings, a brief cooling phase can be set between each cycle so as to prevent the battery from overhe-
ating.
After you have selected the „NiMH" or „NiCd" program in the main menu with the button „BattType/Stop" and con-
firmed this with the button „Start/Enter", you can select the cycle program using the button „+>" or „
shows NiMH accumulator):
", confirm the value using the „Start/Enter" button.
-
<
" (illustration
-
<