Herunterladen Diese Seite drucken

IFM Electronic Ecomat 100 Original-Programmierhandbuch Seite 283

Smartcontroller
Vorschau ausblenden Andere Handbücher für Ecomat 100:

Werbung

ifm
Programmierhandbuch SmartController (CR2530, CR2532) v03.03
Anhang
Index
SubIdx
Parameter name
0x2022
0x0
Output – short circuit
0x1
Short circuit OUT00...OUT07
0x2023
0x0
Output – open circuit
0x1
Open circuit OUT00...OUT07
0x2024
0x0
Output – overload
0x1
Overload OUT00...OUT01
0x2025
0x0
Input analog – overcurrent
0x1
Overcurrent IN00...IN03
Legende
Data type: ro = read only / rw = read and write / wo = write only
Data type
Default
Details
ro
USINT
1
Largest sub-index supported
ro
USINT
0
0 = normal
1 = short circuit
ro
USINT
1
Largest sub-index supported
ro
USINT
0
0 = normal
1 = open circuit
ro
USINT
1
Largest sub-index supported
ro
USINT
0
0 = normal
1 = overload
ro
USINT
1
Largest sub-index supported
ro
USINT
0
0 = normal
1 = overcurrent
283
2018-05-18
Integriertes E/A-Modul: Beschreibung
channels (bit coded)
0b---- ---X = OUT00
0b---- --X- = OUT01
0b---- -X-- = OUT02
0b---- X--- = OUT03
0b---X ---- = OUT04
0b--X- ---- = OUT05
0b-X-- ---- = OUT06
0bX--- ---- = OUT07
channels (bit coded)
0b---- ---X = OUT00
0b---- --X- = OUT01
0b---- -X-- = OUT02
0b---- X--- = OUT03
0b---X ---- = OUT04
0b--X- ---- = OUT05
0b-X-- ---- = OUT06
0bX--- ---- = OUT07
channels (bit coded)
0b---- ---X = OUT00
0b---- --X- = OUT01
channels (bit coded)
0b---- ---X = IN00
0b---- --X- = IN01
0b---- -X-- = IN02
0b---- X--- = IN03

Werbung

loading

Diese Anleitung auch für:

Cr2530