Herunterladen Diese Seite drucken

IFM Electronic Ecomat 100 Original-Programmierhandbuch Seite 270

Smartcontroller
Vorschau ausblenden Andere Handbücher für Ecomat 100:

Werbung

ifm
Programmierhandbuch SmartController (CR2530, CR2532) v03.03
Anhang
Index
S-Idx
Parameter name
0x16
Configuration OUT05
0x17
Configuration OUT06
0x18
Configuration OUT07
0x2000
0x19
Configuration OUT08
0x1A
Configuration OUT09
0x2000
0x1B
Configuration OUT10
0x1C
Configuration OUT11
0x2000
0x1D
Configuration OUT12
0x1E
Configuration OUT13
0x1F
Configuration OUT14
0x20
Configuration OUT15
0x2001
0x0
PWM frequency
0x1
PWM frequency OUT00
0x2
PWM frequency OUT01
0x3
PWM frequency OUT02
0x4
PWM frequency OUT03
0x5
PWM frequency OUT04
0x6
PWM frequency OUT05
0x7
PWM frequency OUT06
0x8
PWM frequency OUT07
0x9
PWM frequency OUT08
0xA
PWM frequency OUT09
0xB
PWM frequency OUT10
0xC
PWM frequency OUT11
0x2002
0x0
Current value
0x1
Current value OUT00
0x2
Current value OUT01
0x2004
0x0
P-value
Data type
Default
Details
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
15 = 0x0F
16 = 0x10
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
15 = 0x0F
16 = 0x10
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
15 = 0x0F
16 = 0x10
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
rw
USINT
2
0 = 0x00
2 = 0x02
rw
USINT
2
0 = 0x00
2 = 0x02
rw
USINT
2
0 = 0x00
2 = 0x02
rw
USINT
2
0 = 0x00
2 = 0x02
ro
USINT
12
Largest sub-index supported
rw
UINT
100
20...250
rw
UINT
100
20...250
rw
UINT
100
20...250
rw
UINT
100
20...250
rw
UINT
100
20...250
rw
UINT
100
20...250
rw
UINT
100
20...250
rw
UINT
100
20...250
rw
UINT
100
20...250
rw
UINT
100
20...250
rw
UINT
100
20...250
rw
UINT
100
20...250
ro
USINT
2
Largest sub-index supported
ro
UINT
0
0...2 000
ro
UINT
0
0...2 000
ro
USINT
2
Largest sub-index supported
270
Integriertes E/A-Modul: Beschreibung
off
Input OUT05
binary plus switched
PWM output
binary plus switched with diagnosis
binary plus switched with diagnosis + protection
off
Input OUT06
binary plus switched
PWM output
binary plus switched with diagnosis
binary plus switched with diagnosis + protection
off
Input OUT07
binary plus switched
PWM output
binary plus switched with diagnosis
binary plus switched with diagnosis + protection
off
Input OUT08
binary plus switched
PWM output + PWM output, voltage controlled
off
Input OUT09
binary plus switched
PWM output + PWM output, voltage controlled
off
Input OUT10
binary plus switched
PWM output
off
Input OUT11
binary plus switched
PWM output
off
Input OUT12
binary plus switched
off
Input OUT13
binary plus switched
off
Input OUT14
binary plus switched
off
Input OUT15
binary plus switched
OUT00 PWM frequency [Hz]
OUT01 PWM frequency [Hz]
OUT02 PWM frequency [Hz]
OUT03 PWM frequency [Hz]
OUT04 PWM frequency [Hz]
OUT05 PWM frequency [Hz]
OUT06 PWM frequency [Hz]
OUT07 PWM frequency [Hz]
OUT08 PWM frequency [Hz]
OUT09 PWM frequency [Hz]
OUT10 PWM frequency [Hz]
OUT11 PWM frequency [Hz]
OUT00 output current [mA]
OUT01 output current [mA]
2018-05-18

Werbung

loading

Diese Anleitung auch für:

Cr2530