Herunterladen Diese Seite drucken

IFM Electronic Ecomat 100 Original-Programmierhandbuch Seite 266

Smartcontroller
Vorschau ausblenden Andere Handbücher für Ecomat 100:

Werbung

ifm
Programmierhandbuch SmartController (CR2530, CR2532) v03.03
Anhang
Index
S-Idx
Parameter name
0x3
PDO mapping
0x1A04
0x0
Transmit PDO mapping
Number of mapped objects in
PDO
0x1
PDO mapping
0x2
PDO mapping
0x3
PDO mapping
0x1A05
0x0
Transmit PDO mapping
Number of mapped objects in
PDO
0x1
PDO mapping
0x2
PDO mapping
0x3
PDO mapping
0x4
PDO mapping
0x5
PDO mapping
0x1A06
0x0
Transmit PDO mapping
Number of mapped objects in
PDO
0x1
PDO mapping
0x2
PDO mapping
0x3
PDO mapping
0x1A07
0x0
Transmit PDO mapping
Number of mapped objects in
PDO
0x1
PDO mapping
0x2
PDO mapping
0x3
PDO mapping
0x1A08
0x0
Transmit PDO mapping
Number of mapped objects in
PDO
0x1
PDO mapping
0x2
PDO mapping
0x3
PDO mapping
0x4
PDO mapping
0x1A09
0x0
Transmit PDO mapping
Number of mapped objects in
PDO
0x1
PDO mapping
Data type
Default
Details
rw
UDINT
0
Reserve
rw
USINT
0x02
Mapping Sende-PDO 5 (Periodendauer IN14...IN15)
Anzahl der eingebundenen Applikationsobjekte = 2
rw
UDINT
0x2012 0320
Index 0x2012, SubIndex 0x3
Frequenzeingang 14: Periodendauer des Signals
rw
UDINT
0x2012 0420
Index 0x2012, SubIndex 0x4
Frequenzeingang 15: Periodendauer des Signals
rw
UDINT
0
Reserve
rw
USINT
0x04
Mapping Sende-PDO 6 (Einschaltzeit des Signals an
Frequenzeingang IN12...IN15)
Anzahl der eingebundenen Applikationsobjekte = 4
rw
UDINT
0x2014 0110
Index 0x2014, SubIndex 0x1
Frequenzeingang 12: Einschaltzeit des Signals in ‰
rw
UDINT
0x2014 0210
Index 0x2014, SubIndex 0x2
Frequenzeingang 13: Einschaltzeit des Signals in ‰
rw
UDINT
0x2014 0310
Index 0x2014, SubIndex 0x3
Frequenzeingang 14: Einschaltzeit des Signals in ‰
rw
UDINT
0x2014 0410
Index 0x2014, SubIndex 0x4
Frequenzeingang 15: Einschaltzeit des Signals in ‰
rw
UDINT
0
Reserve
rw
USINT
0x02
Mapping Sende-PDO 7 (Frequenz an IN12...IN13)
Anzahl der eingebundenen Applikationsobjekte = 2
rw
UDINT
0x2015 0120
Index 0x2015, SubIndex 0x1
Frequenzeingang 12: Frequenzwert des Signals in Hz
rw
UDINT
0x2015 0220
Index 0x2015, SubIndex 0x2
Frequenzeingang 13: Frequenzwert des Signals in Hz
rw
UDINT
0
Reserve
rw
USINT
0x02
Mapping Sende-PDO 8 (Frequenz an IN14...IN15)
Anzahl der eingebundenen Applikationsobjekte = 2
rw
UDINT
0x2015 0320
Index 0x2015, SubIndex 0x3
Frequenzeingang 14: Frequenzwert des Signals in Hz
rw
UDINT
0x2015 0420
Index 0x2015, SubIndex 0x4
Frequenzeingang 15: Frequenzwert des Signals in Hz
rw
UDINT
0
Reserve
rw
USINT
0x03
Mapping Sende-PDO 9 (Fehlermerker OUT00...OUT07)
Anzahl der eingebundenen Applikationsobjekte = 3
rw
UDINT
0x2022 0108
Index 0x2022, SubIndex 0x1
OUT00...OUT07: Merker "Kurzschluss" (Bit-codiert)
rw
UDINT
0x2023 0108
Index 0x2023, SubIndex 0x1
OUT00...OUT07: Merker "Leiterbruch" (Bit-codiert)
rw
UDINT
0x2024 0108
Index 0x2024, SubIndex 0x1
OUT00...OUT01: Merker "Überlast" (Bit-codiert)
rw
UDINT
0
Reserve
rw
USINT
0x04
Mapping Sende-PDO 10 (Systemmerker)
Anzahl der eingebundenen Applikationsobjekte = 4
rw
UDINT
0x2040 0110
Index 0x2040, SubIndex 0x1
System-Versorgungsspannung VBBS