Herunterladen Diese Seite drucken

IFM Electronic Ecomat 100 Original-Programmierhandbuch Seite 271

Smartcontroller
Vorschau ausblenden Andere Handbücher für Ecomat 100:

Werbung

ifm
Programmierhandbuch SmartController (CR2530, CR2532) v03.03
Anhang
Index
S-Idx
Parameter name
0x1
P-value OUT00
0x2
P-value OUT01
0x2005
0x0
I-value
0x1
I-value OUT00
0x2
I-value OUT01
0x2006
0x0
PWM dither frequency
0x1
PWM dither frequency OUT00
0x2
PWM dither frequency OUT01
0x3
PWM dither frequency OUT02
0x4
PWM dither frequency OUT03
0x5
PWM dither frequency OUT04
0x6
PWM dither frequency OUT05
0x7
PWM dither frequency OUT06
0x8
PWM dither frequency OUT07
0x9
PWM dither frequency OUT08
0xA
PWM dither frequency OUT09
0xB
PWM dither frequency OUT10
0xC
PWM dither frequency OUT11
0x2007
0x0
PWM dither value
0x1
PWM dither value OUT00
0x2
PWM dither value OUT01
0x3
PWM dither value OUT02
0x4
PWM dither value OUT03
0x5
PWM dither value OUT04
0x6
PWM dither value OUT05
0x7
PWM dither value OUT06
0x8
PWM dither value OUT07
0x9
PWM dither value OUT08
0xA
PWM dither value OUT09
0xB
PWM dither value OUT10
0xC
PWM dither value OUT11
0x2012
0x0
Period input
0x1
Period duration IN12
0x2
Period duration IN13
0x3
Period duration IN14
0x4
Period duration IN15
0x2013
0x0
Period input
number of periods for average
0x1
Number of periods IN12
0x2
Number of periods IN13
0x3
Number of periods IN14
0x4
Number of periods IN15
Data type
Default
Details
rw
USINT
30
0...255
rw
USINT
30
0...255
ro
USINT
2
Largest sub-index supported
rw
USINT
20
0...255
rw
USINT
20
0...255
ro
USINT
12
Largest sub-index supported
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
rw
UINT
0
0...PWMfreq / 2
ro
USINT
12
Largest sub-index supported
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
rw
UINT
0
0...1 000
ro
USINT
4
Largest sub-index supported
ro
UDINT
0
IN12 period duration [µs]
ro
UDINT
0
IN13 period duration [µs]
ro
UDINT
0
IN14 period duration [µs]
ro
UDINT
0
IN15 period duration [µs]
ro
USINT
4
Largest sub-index supported
rw
USINT
4
1...255
rw
USINT
4
1...255
rw
USINT
4
1...255
rw
USINT
4
1...255
271
Integriertes E/A-Modul: Beschreibung
OUT00 P-value for current control
OUT01 P-value for current control
OUT00 I-value for current control
OUT01 I-value for current control
OUT00 PWM dither frequency [Hz]
OUT01 PWM dither frequency [Hz]
OUT02 PWM dither frequency [Hz]
OUT03 PWM dither frequency [Hz]
OUT04 PWM dither frequency [Hz]
OUT05 PWM dither frequency [Hz]
OUT06 PWM dither frequency [Hz]
OUT07 PWM dither frequency [Hz]
OUT08 PWM dither frequency [Hz]
OUT09 PWM dither frequency [Hz]
OUT10 PWM dither frequency [Hz]
OUT11 PWM dither frequency [Hz]
OUT00 PWM dither value [‰]
OUT01 PWM dither value [‰]
OUT02 PWM dither value [‰]
OUT03 PWM dither value [‰]
OUT04 PWM dither value [‰]
OUT05 PWM dither value [‰]
OUT06 PWM dither value [‰]
OUT07 PWM dither value [‰]
OUT08 PWM dither value [‰]
OUT09 PWM dither value [‰]
OUT10 PWM dither value [‰]
OUT11 PWM dither value [‰]
IN12 number of periods
IN13 number of periods
IN14 number of periods
IN15 number of periods
2018-05-18