Herunterladen Diese Seite drucken

IFM Electronic Ecomat 100 Original-Programmierhandbuch Seite 269

Smartcontroller
Vorschau ausblenden Andere Handbücher für Ecomat 100:

Werbung

ifm
Programmierhandbuch SmartController (CR2530, CR2532) v03.03
Anhang
Index
S-Idx
Parameter name
0xC
Configuration IN11
0x2000
0xD
Configuration IN12
0xE
Configuration IN13
0xF
Configuration IN14
0x10
Configuration IN15
0x2000
0x11
Configuration OUT00
0x12
Configuration OUT01
0x2000
0x13
Configuration OUT02
0x14
Configuration OUT03
0x15
Configuration OUT04
Data type
Default
Details
rw
USINT
10
0 = 0x00
10 = 0x0A
11 = 0x0B
rw
USINT
1
0 = 0x00
1 = 0x01
14 = 0x0E
19 = 0x13
20 = 0x14
21 = 0x15
22 = 0x16
23 = 0x17
rw
USINT
1
0 = 0x00
1 = 0x01
14 = 0x0E
19 = 0x13
20 = 0x14
21 = 0x15
22 = 0x16
23 = 0x17
rw
USINT
1
0 = 0x00
1 = 0x01
14 = 0x0E
19 = 0x13
20 = 0x14
21 = 0x15
22 = 0x16
23 = 0x17
rw
USINT
1
0 = 0x00
1 = 0x01
14 = 0x0E
19 = 0x13
20 = 0x14
21 = 0x15
22 = 0x16
23 = 0x17
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
5 = 0x05
15 = 0x0F
16 = 0x10
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
5 = 0x05
15 = 0x0F
16 = 0x10
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
15 = 0x0F
16 = 0x10
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
15 = 0x0F
16 = 0x10
rw
USINT
2
0 = 0x00
2 = 0x02
4 = 0x04
15 = 0x0F
16 = 0x10
269
Integriertes E/A-Modul: Beschreibung
off
Input IN11
binary plus switched
binary plus switched with diagnosis
off
Input IN12
binary plus switched, digitally monitored
frequency 0...30 000 Hz
period duration
period duration as ratio 0...1 000 ‰
counting up
counting down
incremental encoder
off
Input IN13
binary plus switched, digitally monitored
frequency 0...30 000 Hz
period duration
period duration as ratio 0...1 000 ‰
counting up
counting down
incremental encoder
off
Input IN14
binary plus switched, digitally monitored
frequency 0...30 000 Hz
period duration
period duration as ratio 0...1 000 ‰
counting up
counting down
incremental encoder
off
Input IN15
binary plus switched, digitally monitored
frequency 0...30 000 Hz
period duration
period duration as ratio 0...1 000 ‰
counting up
counting down
incremental encoder
off
Input OUT00
binary plus switched
PWM output
current control
binary plus switched with diagnosis
binary plus switched with diagnosis + protection
off
Input OUT01
binary plus switched
PWM output
current control
binary plus switched with diagnosis
binary plus switched with diagnosis + protection
off
Input OUT02
binary plus switched
PWM output
binary plus switched with diagnosis
binary plus switched with diagnosis + protection
off
Input OUT03
binary plus switched
PWM output
binary plus switched with diagnosis
binary plus switched with diagnosis + protection
off
Input OUT04
binary plus switched
PWM output
binary plus switched with diagnosis
binary plus switched with diagnosis + protection
2018-05-18