Herunterladen Inhalt Inhalt Diese Seite drucken

John Bean B 2000P Betriebsanleitung Seite 200

Inhaltsverzeichnis

Werbung

8
7-55
7-56
7-43
7-57
200
Operation
Reading of error code E9
If E9 is read out, at least one error was made with
respect to the sequence of operations when performing
optimisation (System messages
— Abort the optimisation program by pressing the
STOP key and, if desired, start optimisation once
again.
Fig. 7-55 MINIMISATION "9"
Clamp the wheel on the balancer.
Rotate the wheel such that the valve is exactly
perpendicular to and above the main shaft.
Confi rm the valve position by pressing key 8.
The MINIMISATION "10" screen (Fig. 7-56) is
displayed.
Figura 7-56 MINIMISATION "10"
START is displayed on the screen.
Spinn the wheel.
A measuring run is performed.
The BALANCING screen (Fig. 7-43) is displayed.
Finish weight Minimisation
Fig. 7-43 BALANCING
Balance the wheel according to the readings.
If the wheel quiet running conditions cannot be
improved on, the following message is displayed:
Fig. 7-57
H0 Wheel running conditions cannot be improved by
optimisation.
..
_
..........
F
7.1).

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis