Pool control system Control 1.3 / Operation
6.9 Settings menu extras
6.9.1 Service level
The service level for the control system can be configured in the submenu Extras/Service level.
You must enter the four-digit service code for the control system in this menu. As a specialist dealer, you
can request this from the manufacturer. The service code may only be passed on to specialists!
The service level is automatically deactivated if the control system detects no inputs for more than
5 minutes.
6.9.2 Freely programmable terminals
The freely programmable terminals can be configured in the submenu Extras/Freely programmable
terminals. The terminals for speed 2 (A13, potential-free closer), speed 3 (A14, potential-free closer), clear
rinsing (A7, 230V-3A), solar pump (A2, 230V-3A), lowering valve (A8, 230V-3A) and floor valve (A10, 230-3A)
can be assigned differently in the control system if they are not already being used. The following modes
can be selected for each terminal:
•
Time switch
•
Switching times: The control system switches the terminal according to defined switching times,
which are set identically to the logic of the filter pump switching times.
•
Active: The terminal must be set as ACTIVE so that it can be switched on after the switching times.
•
Locked: If "active" is set here, the terminal is only switched when the filter pump is also active at the
same time. If "inactive" is set here, the terminal is switched independently of the filter pump.
•
Impulse:
•
Length on: The control system sets the terminal to active for the defined running time
(max. 240 min).
•
Length off: The control system sets the terminal to inactive for the defined running time
(max. 240 min).
•
Active: The terminal must be set as "active" so that it can be switched on after the set times.
•
Locked: If "active" is set here, the terminal is only switched when the filter pump is also active at
the same time. If "inactive" is set here, the terminal is switched independently of the filter pump.