Herunterladen Inhalt Inhalt Diese Seite drucken

Behncke Control 1.3 Betriebsanleitung Seite 86

Vorschau ausblenden Andere Handbücher für Control 1.3:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Pool control system Control 1.3 / Operation
Level regulator
Pool type
Filling valve
Delay
Dosing technology
If a channel tank extension is required to regulate the level of an overflow pool (channel pool), it must be
connected to the BUS terminals. The hanging electrodes are connected to the channel tank extension.
Please consider the instruction manual for the channel tank extension circuit diagrams. The float switch
for regulating the level of a skimmer pool must be connected to terminal E7.
If a (magnetic) filling valve is present, it must be connected to terminal A9.
6.7.7 ECO functions
The ECO functions can be configured in the submenu Processing/ECO function. This is shown in figure 8.
Floor valve: Defines whether a floor valve has been connected. For closed pool covers, the floor valve is
switched on automatically and suction is provided via the floor drain.
Cover: Defines the speed of the filter pimp for closed pool covers
The end position switch of the pool cover must be connected to terminal E8.
The floor valve must be connected to output A10.
27
Channel
Available
5 s
Off
Figure 7: Level regulator
Flow switch
Flow switch
Forced pump
Model
Delay
Figure 8: ECO functions
Level regulator
Max. filling time
Max. daily filling time
Forced HE5
Forced HE6
Available
On
Closer
5 s
0 min
0 min
On
On
Inhaltsverzeichnis