Pool control system Control 1.3 / Operation

6.8 Warming settings menu

6.8.1 Heating

Auxiliary heating is configured in the submenu Warming/Heating. This is shown in figure 9.
The following parameters can be adjusted:
Sensor: Defines whether a water sensor is present. The heating function can only be accessed
if a sensor is present. If a water sensor is present, its temperature values are displayed on
the start screen.
Heating: Defines whether the heating function for warming up the water temperature should be used.
Temperature: Defines the target value for the pool water.
Delay: Defines the delay time after which the heating should be activated once the temperature has
dropped below the target value (max. 20 min).
Overrun: Defines how long the filter pump should continue to run at normal speed after the target
temperature has been achieved, regardless of the switching times.
Forced: Defines whether the filter pump should be switched on for heating purposes outside of the
switching times.
Hysteresis: Defines the minimum required difference between the target temperature and the actual
temperature of the pool water for the heating to be activated.
Sensor
Heating
Temperature
Delay
Water sensor (PT1000) must be connected to terminal E4.
The heating pump/heating magnetic valve must be connected to terminal A3 (230V).
The heating release signal must be connected to terminal A12.
29
Heating
Available
On
27.5°C
0 min
Figure 9: Heating
Heating
0 min
Overrun
On
Forced
1.0 K
Hysteresis