TEMPERATURE:
The water temperature and the collector temperature / external temperature are shown in the
middle at the bottom of the screen. The collector temperature is only shown if a sensor has been
chosen in the menu Solar. The water temperature is only shown if a sensor has been chosen in
the menu Heating.
MEASUREMENT AND CONTROL TECHNOLOGY:
The measured values from the measurement and control technology are shown beneath the
temperatures. They are only shown if measurement and control technology has been connected
and the inputs have been set for measurement and control technology.
SERVICE LEVEL:
If a red mark is shown at the upper edge of the screen, the user is in the service level and has
access to all the menu items.

6.6 General settings menu

6.6.1 Query system status

The following control system conditions can be queried in the submenu "System status".
If one of the possible peripheral devices has not been set up, its condition is not shown.
Filter pump condition (filter pump)
Backwash valve condition (backwashing)
Floor valve condition (floor valve)
Solar valve / collector valve condition (solar)
Auxiliary heating condition (heating)

6.6.2 Query system information

In the submenu "System information", you can query the current software version under "Version" and you
can query connection to the internet. An active internet connection is shown with "Portal XML" OK

6.6.3 Query carrying values

The following control system operating numbers can be queried in the submenu "Carrying values".
If one of the possible peripheral devices has not been set up, its carrying values are not shown.
Total filter running time in hours (filter)
Filter running time in the system since the last backwashing in hours (filter since FR)
Total running time of the solar heating in hours (solar)
Total running time of the auxiliary heating in hours (heating)
Total running time of the fresh water valve in hours (fresh water)
Total number of filter backwashes (backwashing)
Total number of clear rinses (clear rinsing)

6.6.4 Set date and time

In the submenu "Date/time", the user can set the current date and the current time in the control system.
The values are stored in the control system so that the values don't need to be set again after a power
outage.
Pool control system Control 1.3 / Operation