Fault/error message
The values from the measuring
and control system are displayed
in orange.
Order of hanging electrodes
Overcurrent on the filter pump
Fault on the frequency converter
Cable breakage at phase "X"
Sequence of the phases incorrect
Temperature sensor fault
Lack of water in the overflow tank
Flow switch
No filter cleaning by OmniTronic
Filter cleaning aborted
Lack of water
Filter cleaning aborted
Flow switch
Max. filling time reached
Max. daily filling time reached
Overfilling (HE6)
Medium "X" empty
Pool control system Control 1.3 / Malfunction
The system is outside of the filter running times. The last value
measured during filter running times is displayed and "frozen".
The channel tank extension hanging electrodes are addressed
in an incorrect order. Please check whether they have been
connected correctly or if they have come loose on the bracket
in the tank.
The nominal motor current is too high. Please check the pump.
With an external frequency converter there is a malfunction.
Please check the frequency converter.
The control system identifies a cable breakage at phase X.
Please check the supply lines.
The incorrect pump type has been set up or the pump phases
have been connected incorrectly. Please check the supply lines
The measured temperature values are outside of the logic limits
in the control system. Please check the lines and temperature
sensor for damage.
The overflow tank is almost empty (HE2 has no contact with
water), meaning there is a risk of the pump running dry.
Please check the filling valve.
No current detected via the flow switch. There is a risk of the
pump running dry.
Please check the pump and the flow switch.
The OmniTronic has not cleaned the filter within the defined
time. Please check the settings and the OmniTronic.
Filter cleaning was aborted due to a lack of water.
Filter cleaning was aborted due to there being no current at the
flow switch.
The filling valve is activated for the piece for longer than the
maximum permissible filling time. Please check the pool for
possible leaks and the adjusted values.
The filling valve is activated for the day for longer than the
maximum permissible daily filling time. Please check the pool
for possible leaks and the adjusted values.
The hanging electrode HE6 has detected that the overflow tank
is completely full and is overflowing. Please check the position
of HE6 in the tank and the settings.
The fill level sensors have determined that medium X is empty.
Please check the fill level and replace the medium with
a new one.
Reason
36