6.7.5 Flow switch settings
The flow switch can be configured in the submenu Processing/Flow switch.
This is shown in figure 4.
•
Flow switch: Defines whether a flow switch has been connected
•
Forced pump: Defines whether the filter pump should be stopped if there is an error message
from the flow switch.
•
Model: Defines the switching direction for the flow switch (closer or opener)
•
Delay: Defines the time until the control system issues an error message due to the input signal from
the flow switch. (5 - 600 s)
The flow switch must be connected to terminal E6.
6.7.6 Flow switch settings
The level regulator is configured in the submenu Processing/Level regulator. This is shown in figure 7.
•
Pool type: Defines whether a skimmer pool or channel pool is present. For channel pools, you also
need a Behncke channel tank extension (Item #: 39019095-EXT).
•
Filling valve: Defines whether a filling valve (magnetic valve) is connected
•
Model: Only available for skimmer pools. Defines the switch type for the float switch (closer or opener)
•
Delay: Defines the time until the control system triggers the filling valve due to an input signal.
•
Dosing technology: Defines whether the dosing technology should be deactivated for the time in which
the filling valve is active.
•
Max. filling time: Defines the maximum time that the filling valve can be continuously controlled. If the
time is exceeded, the filling valve is switched off and an error message is displayed.
•
Max. daily filling time: Defines the maximum time that the filling valve can be controlled during the day.
If the time is exceeded, the filling valve is switched off and an error message is displayed.
•
Forced HE5: Defines whether the filter pump should be forced to switch on in the event of the hanging
electrode HE5 coming into contact with water (only for channel pools).
•
Forced HE6: Defines whether a forced backwash should happen in the event of the hanging electrode
HE6 coming into contact with water (only for channel pools).
Flow switch
Flow switch
Forced pump
Model
Delay
Figure 6: Flow switch
Pool control system Control 1.3 / Operation
Available
On
Closer
5 s
26