Installation
6 .4
Connecting the cable to the panel
Insert the plug of the cable into the 12 V connection
of the panel (Fig. 6).
Fig. 6
Lay cables in loops to avoid tension.
6 .5
Replacing the connector cable
The existing connector cable without termination resis-
tor must be replaced with the panel cable with termina-
tion resistor included in the scope of delivery.
Carefully unplug the connector cable (Fig. 7) up-
wards from the panel.
Fig. 7
To disconnect the two electrical wires at the other end
of the connector cable from the fuse terminal:
Turn both fastening screws with a screwdriver
(Fig. 8-1, Fig. 8-3).
Pull both cables out of the fuse terminal
(Fig. 8-2, Fig. 8-4).
18
EN
1
2
Fig. 8
The connector cable is no longer needed.
The red electrical wire of the panel cable must be fed
into the opening of the fuse terminal, from where a red
electrical wire leads out.
The black electrical wire of the panel cable must be
fed into the opening of the fuse terminal, from where a
black electrical wire leads out.
To secure the two electrical wires of the panel cable in
the fuse terminal:
Insert both electrical wires of the panel cable into
the respective opening of the fuse terminal as far as
they will go (Fig. 9-1, Fig. 9-3).
Turn both fastening screws with a screwdriver
(Fig. 9-2, Fig. 9-4) until both electrical wires are
firmly fixed in the fuse terminal.
2
1
Fig. 9
Insert the plug of the panel cable (Fig. 10) into the
panel carefully from above without kinking the panel
cable at the transition between the panel cable and
the plug.
Truma iNet X Connect
3
4
4
3
47000-00194 · 00 · 10/2024