Touch Panel connection
Only connection the Touch Panel (TP) using a Y-adapter (Y) to
a Power Module (PM).
Install the Y-adapter (part no. C30000-03300) in a place (wall
or floor) protected against moisture and wetness close to
the Power Module (PM). Fix the Y-adapter with cable ties if
necessary.
COM1
COM1
COM2
PM
-Y
+Y
The Y-adapter connection cables may not be extended.
Connecting the Truma Combi heating
A TIN cable is necessary for connection of the heating to the
COM3 connection of a module (PM).
CAN
COM1
COM2
COM3
PM
PM
COM3
TIN
TIN cable 3 m (part no. C30000-05000)
TIN cable 6 m (part no. C30000-05100)
10
TP
Y
CAN
CAN
COM1
COM2
PM
TIN
Combi
Connecting the Alde Compact 3010 heating
An interface (AVI) is necessary to connection the Alde heating
Compact 3010 to the Vicon 2 bus system.
Connect the device using the interface with COM3 of a
module (PM).
The Alde room temperature sensor (A) must be
connected at the AVI.
R
CAN
COM1
COM2
COM3
PM
COM3
A
Alde Room temperature sensor
AVI
Alde-Vicon-Interface (part no. C30000-03500)
TIN
TIN cable 3 m (part no. C30000-05000)
TIN cable 6 m (part no. C30000-05100)
COM1
R
COM2
Adaption / consumers connection
Adaption of the connection (of consumers) only takes
place through the vehicle manufacturer.
CAN
CAN
COM1
COM2
PM
PM
TIN
A
AVI
Alde
Compact
3010
COM1
R
COM2