Access to compressed air safety valve
Item
Description
1
Cover plate
The product has one or more safety valves.
To gain access to the safety valve (item 2), the cover plate (item 1) must be
removed.
7.2.13
Maintenance schedule
Activities
Emptying the dust
collection container
Draining the
condensate from the
compressed air vessel
Draining condensate
from the compressed
air maintenance unit
Checking the belt drive
for tension and
alignment
15028844-00
Fig. 115: Access to compressed air safety valve
Tab. 88: Access to compressed air safety valve
Time/interval
As required
As required, but at least
once per month
As required, however at
least once per week
Initially after 10
ventilator start-ups,
then every 1600
Item
Description
2
Cover plate
Information:
Only if belt drive
available