DANGER
Danger of electric voltage!
Products with extraction power control (frequency inverters) are
intended for protection by line protection fuses.
If the product is operated on a mains supply with a residual current
circuit breaker (RCCB) connected upstream, the following must be
observed.
Since the operation of the frequency inverter on the protective earth
conductor can cause a direct current, the residual current circuit breaker
(RCCB) connected in series with the mains must meet the following
requirements.
Products with 16/ 32 Ampere – Plug
Category
Rated current
type:
Type B
40 A
Type B
63 A
Tab. 52: Requirements for residual current circuit breaker
DANGER
Suspended loads
Tipping or falling loads lead to severe to fatal injuries.
•
Never step under suspended loads.
•
Always remain outside the danger zone.
•
Observe the total weight, attachment points and centre of gravity of
the load.
•
Observe the transport instructions and symbols on the transported
goods.
WARNING
Health hazards caused by welding fume particles
Do not inhale welding dust / smoke! Serious injury to the lungs and
respiratory tract is possible!
Sweat smoke contains substances that can cause cancer!
Skin contact with cutting and welding fumes etc. can cause skin irritation
in sensitive persons!
15028844-00
Tripping fault current Note
30 mA
30 mA
- 109 -
short time-delayed
short time-delayed
EN