NOTE
Products with W3 certification according to requirements for W3/IFA
certified welding fume separation class. (See "Technical data" chapter)
The W3 approval becomes void if:
The product is used other than as intended or is subject to
constructive modifications.
Non-original spare parts, in accordance with the spare parts list, are
used.
Only original replacement filters, because they guarantee the necessary
filter efficiency and are matched to the product and its performance
characteristics.
Switch the product off using the on/off switch.
Secure the product against unintentional switching on. If available, pull
out the mains plug or secure the main switch in the 0 position with a
padlock.
Disconnect the pressure supply, if present, and let the compressed air
present in the product flow out via the condensate drain valve.
7.2.3 Filter replacement – safety filter for dust collection
container
Depending on usage, but at least once per week, check and replace the
pre-filter mat in the safety filter if necessary.
The safety filter is located in the fan housing section and is connected to
the dust collection container via a hose.
The increased negative pressure from the fan section means the disposal
bag in the dust collection container cannot suck itself up.
A heavily soiled safety filter signals that there is a leak or that the disposal
bag has been damaged.