Wärmepumpen mit lueftgekuehlter verfluessigung und axialventilatoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

RAB
Base electrical resistance
LKD
Refrigerant leakage detector (Leak Detector)
DSP
Double set-point via digital consensus (incompatible with the CS accessory)
CS
Scrolling set point via analogue signal 4-20 mA (incompatible with the DSP accessory)
Control of the MIN/MAX values of the power supply voltage and back-up battery; this is used to monitor the power supply voltage and
CMT1
switch off the unit if the value goes out of tolerance. In this case the backup battery guarantees the perfect closure of the electronic
expansion valve
BT
Low temperature of water produced
EEM
Energy Meter. Measure and display values of the electrical units - See specific section for more information
SS
Interface RS485 for serial dialogue with other devices (proprietary protocol, Modbus RTU protocol)
FTT10
LON interface for serial communication with other devices (LON protocol)
BE
Ethernet interface for serial communication with other devices (BACnet IP, ModBus TCP/IP protocol)
BM
RS485 interface for serial communication with other devices (BACnet MS/TP protocol)
RPB
Coil protection nets with accident prevention function (to be used as an alternative to the FMB accessory)
FMB
Mechanical filters to protect the coils, with leaf protection function (to be used as an alternative to the RPB accessory)
IMB
Protective packaging
DVS
High pressure and low pressure double safety valve with exchanger tap
SAG
Rubber anti-vibration mounts (supplied not installed)
Electrical panel roof (sizes 2120÷2150 – 14÷16, for sizes 270÷2100 – 10÷13 it is standard)
TQE
RAP
Unit with pre-painted copper/aluminium condensing coils
BRR
Unit with copper/copper condensing coils
BRH
Units with copper/aluminium condensing coils with hydrophilic treatment
VPF_R+IN-
Variable Primary Flow by Rhoss. The accessory includes management via inverter of the primary side pump(s) supplied as optional
VERTER
P1/DP1 (check that the total water content is at least 5lt/kW), the temperature probes and the management software of the chiller
P1/DP1
VPF_R+IN-
Variable Primary Flow by Rhoss. The accessory includes management via inverter of the primary side pump(s) supplied as optional
VERTER
P1/DP1 (check that the total water content is at least 5lt/kW), the temperature probes and the management software of the chiller
P2/DP2
P1/DP1 pump adjustment (which must be chosen as optional) via inverter for calibration/commissioning of the system. At the end of
INV_P1/ DP1
calibration, the unit must work at a constant flow rate.
P2/DP2 pump adjustment (which must be chosen as optional) via inverter for calibration/commissioning of the system. At the end of
INV_P2/ DP2
calibration, the unit must work at a constant flow rate.
Accessories supplied separately
KTRD
Thermostat with display
Remote keypad for control at a distance with LCD display and same functions as the machine. Connection must be made with a 6-wire
KTR
telephone cable (maximum distance 50 m) or with KRJ1220/KRJ1230 accessories. For greater distances up to 200 m, use an AWG
20/22 shielded cable (4 wires+shield, not supplied) and the KR200 accessory
KRJ1220
Connection cables for KTR (20 m length)
KRJ1230
Connection cables for KTR (30 m length)
KR200
KTR remote control Kit (distance between 50 and 200m)
KRS485
Interface RS485 for serial dialogue with other devices (proprietary protocol, Modbus RTU protocol)
KFTT10
LON interface for serial communication with other devices (LON protocol)
KBE
Ethernet interface for serial communication with other devices (BACnet IP protocol)
KBM
RS485 interface for serial communication with other devices (BACnet MS/TP protocol)
KUSB
RS485/USB serial converter (USB cable supplied)
Refer to the price list to verify the compatibility of any accessory.