B. Braun Aesculap DAVID 3 PV430 Gebrauchsanweisung Seite 5

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
Contents
1.
Applicable to
2.
Safe handling
3.
Product description
3.1
Scope of supply
3.2
Components required for operation
3.3
Intended use
3.4
Operating principle
4.
Preparation and setup
4.1
First use
4.2
Stacking of units
4.3
Moving stacks of units
4.4
Presetting the correct voltage
5.
Working with the DAVID 3 PV430/PV432/PV435 3-chip video
camera system
5.1
System set-up
5.2
Function checks
5.3
Safe operation
5.4
Ending the application
6.
Validated reprocessing procedure
6.1
General safety instructions
6.2
General information
6.3
Preparations at the place of use
6.4
Preparation before cleaning
6.5
Cleaning/disinfection
6.6
Wipe disinfection for electrical devices without sterilization
6.7
Inspection, maintenance and checks
6.8
Packaging
6.9
Sterilization
6.10 Sterilization for the US market
6.11 Storage
7.
Maintenance
7.1
Fuse replacement
8.
Troubleshooting list
9.
Technical Service
10.
Accessories/Spare parts
11.
Technical data
11.1 Ambient conditions
12.
Disposal
13.
Distributor in the US/Contact in Canada for product
information and complaints
1.
Applicable to
3
For item-specific instructions for use and information on material
compatibility,
see
3
www.extranet.bbraun.com
4
4
4
4
2.
Safe handling
4
CAUTION
5
Federal law restricts this device to sale by, or on order of a physician!
5
Remove the transport packaging and clean the new product, either
6
manually or mechanically, prior to its initial sterilization.
6
Prior to use, check that the product is in good working order.
6
To prevent damage caused by improper setup or operation, and in order
not to compromise warranty and manufacturer liability:
6
– Use the product only according to these instructions for use.
6
– Follow the safety and maintenance instructions.
7
– Only combine Aesculap products with each other.
7
– Adhere to application instructions according to relevant norms.
9
Ensure that the product and its accessories are operated and used only
9
by persons with the requisite training, knowledge, or experience.
9
Keep the instructions for use accessible for the user.
9
Always adhere to applicable standards.
9
Do not operate the product in the vicinity of flammable anesthetics.
9
Check the power cord for leakage currents and correct grounding at
10
regular intervals.
10
Check the power adapter regularly to ensure it is in tact and working
10
correctly.
10
Connect the device to a suitable power source.
11
Unplug the device by pulling on the plug, and never on the power cord.
11
Note
11
The connection of electronic devices to a multiple socket leads to the con-
11
struction of a system and can lead to a reduced level of safety.
11
12
Risk of fatal injury from electric shock!
13
Do not touch the patient and connections of the
13
DANGER
camera control unit at the same time.
14
14
Malfunction in connection with magnetic reso-
15
nance!
Do not use product in a magnetic resonance
CAUTION
15
environment.
Note
To completely disconnect the device from the power supply, remove the
plug from the mains socket on the rear of the device. Make sure access is
unobstructed.
also
the
Aesculap
Extranet
at
3

Werbung

loading