HEAT SOURCES > S5.x
Parameter
Parameter description
MINIMUM TEMPERATURE OF LIQUID FUEL BOILER
S5.1
Setting is adjusted with a button on the controller.
MAXIMUM TEMPERATURE OF LIQUID FUEL BOILER
S5.2
BURNER HYSTERESIS
S5.3
-1 - inverted burner output operation regardless boiler temperature sensor KF
0 - inverted burner output operation regardless boiler temperature sensor KF
1 do 20 °C - burner hysteresis (+ 3/5 of hysteresis, - 2/5 of hysteresis)
MINIMUM TEMPERATURE OF RETURN- PIPE
S5.4
INTO THE BOILER RLKF
BOILER OPERATION MODE
S5.5
0 - boiler is sustained on minimum boiler temperature
1 - boiler is switched OFF, if there is no request for heating in night time
2 - boiler is switched OFF, if there is no request for heating in day and night time
BOILER TEMPERATURE INCREASE FOR THE
S5.6
MIXING HEATING CIRCUIT PURPOSE
BOILER TEMPERATURE INCREASE FOR THE
S5.7
D. H. W. WARMING PURPOSE
MINIMUM TEMPERATURE OF SOLID FUEL BOILER
S5.8
Setting is adjusted with a button on the controller.
MAXIMUM TEMPERATURE OF SOLID FUEL BOILER
S5.9
AND HEAT ACCUMULATOR
MINIMUM TEMPERATURE OF HEAT
S5.10
ACCUMULATOR
HEAT ACCUMULATOR OPERATION TEMPERATURE
S5.11
For special hydraulic schemes only!
INTEGRATION LIMIT FOR HEAT LOSS
S5.12
CALCULATION, WHEN SWITCHING BETWEEN TWO
HEAT SOURCES
Higher value means bigger delay for switchover to liquid fuel boiler and vice versa.
Service settings manual
Setting span
10 ÷ 90
60 ÷ 160
-1 ÷ 20
10 ÷ 90
0 ÷ 2
0 ÷ 25
5 ÷ 25
10 ÷ 90
60 ÷ 160
20 ÷ 70
10 ÷ 90
0,1 ÷ 3,0
46
Units Default
setting
°C
70
°C
90
K
8
°C
50
-
1
K
5
K
12
°C
65
°C
90
°C
30
°C
55
-
1