DOMESTIC HOT WATER > S4.x
Parameter
Parameter description
DOMESTIC HOT WATER PRIORITY BEFORE
S4.1
MIXING HEATING CIRCUIT
0 - domestic hot water has no priority before mixing heating circuit
1 - domestic hot water has priority before mixing heating circuit
DOMESTIC HOT WATER PRIORITY
S4.2
BEFORE DIRECT HEATING CIRCUIT
0 - domestic hot water has no priority before direct heating circuit
1 - domestic hot water has priority before direct heating circuit
BLP (A.7) OUTPUT:
S4.3
0 - domestic hot water warming with boiler
1 - domestic hot water warming with electric heater
2 - output operation mode by d. h. w. time program
3 - domestic hot water storage tank without temperature sensor
4 - domestic hot water circulation
5 - operation without temperature difference to the heat source
LIMITING THE REQUIRED D. H. W. TEMPERATURE
S4.4
BY BOILER SWITCHOVER
1 - limiting to 45 °C
2 - limiting to 50 °C
3 - limiting to 55 °C
4 - limiting to 60 °C
MAXIMUM D. H. W. TEMPERATURE
S4.5
HYSTERESIS FOR D. H. W. WARMING
S4.6
CIRCULATION:
S4.7
0 - output is switched OFF,
1 - the pump operates for 1 min and is switched OFF for 9 min,*
2 - the pump operates for 2 min and is switched OFF for 8 min,*
3 - the pump operates for 3 min and is switched OFF for 7 min,*
4 - the pump operates for 4 min and is switched OFF for 6 min,*
5 - the pump operates for 5 min and is switched OFF for 5 min,*
6 - the pump operates for 6 min and is switched OFF for 4 min,*
7 - the pump operates for 7 min and is switched OFF for 3 min,*
8 - the pump operates for 8 min and is switched OFF for 2 min,*
9 - the pump operates for 9 min and is switched OFF for 1 min,*
10 - the pump operates continuously,*
11 - d. h. w. warming with an electric heater,**
12 - pulse operation of the sun collectors pump, if Tkt<Tktmin
13 - 2nd stage of burner on the output for circulation
14 - solid fuel boiler bypass circulation pump
* When the d. h. w. circulation program is in state - ON!
** Operates by the d. h. w. circulation time program!
Service settings manual
5 - limiting to 65 °C
6 - without limitation, with delay
7 - without limitation and delay
44
Setting span
Units Default
setting
0 ÷ 1
-
0 ÷ 1
-
0 ÷ 5
-
1 ÷ 7
-
50 ÷ 90
°C
2 ÷ 20
K
0 ÷ 14
-
0
1
0
3
80
6
5