MINIMUM AMBIENT TEMPERATURE FOR D. H. W.
S2.14
WARMING WITH HEAT PUMP
LIMITATION OF DIFFERENCE BETWEEN VF AND
S2.15
RLF
0 - switch off
1 ÷ 30 K difference
DIRECT HEATING CIRCUIT > S3.x
Parameter
Parameter description
AMPLIFICATION OF ROOM TEMPERATURE
S3.1
DEVIATION FOR DIRECT HEATING CIRCUIT
PARALLEL SHIFT OF THE HEATING CURVE FOR
S3.2
DIRECT HEATING CIRCUIT
BOOST HEATING DURATION BY NIGHT/DAY
S3.3
TEMPERATURE SWITCHOVER DIRECT CIRCUIT
REQUIRED ROOM TEMPERATURE INCREASE BY
S3.4
BOOST HEATING FOR DIRECT HEATING CIRCUIT
UWP2 OPERATION MODE
S3.5
0 - circulation pump for direct heating circuit (standard),
1 - UWP2 switches OFF, when the room temperature is higher than required room
temperature
2 - UWP switches OFF, when P1=OFF
3 - UWP switches OFF, when P2=OFF
4 - UWP switches OFF, when current time program is OFF
HEATING CURVE STEEPNESS FOR ADDITIONAL
S3.6
DIRECT HEATING CIRCUITS
PARALLEL SHIFT OF THE HEATING CURVE FOR
S3.7
ADDITIONAL DIRECT HEATING CIRCUITS
2 ÷ 12 K - Parallel shift of the heating curve for additional direct heating circuits.
13 ÷ 90 °C - Required boiler temperature for additional direct heating circuits.
MAXIMUM TEMPERATURE FOR DIRECT HEATING
S3.8
CIRCUIT
TWO HEAT SOURCES: INVERTED OUTPUT A4:
S3.9
0 - normal mode
1 - inverted mode
Setting span
43
5 ÷ 30
°C
0 ÷ 30
-
Default
Units
setting
0,0 ÷ 3,0
-
-15 ÷ 15
K
0 ÷ 200
min
0 ÷ 8
K
0 ÷ 1
-
1,0 ÷ 2,2
-
2 ÷ 90
-
20 ÷ 150
°C
0 ÷ 1
-
Service settings manual
16
0
1
0
0
4
0
1,2
6
85
1