Total weight [kg]
2.7

Work area

Height [mm]
Length [mm]
Width [mm]
2.8

Speeds

Gear stage slow [min
Gear stage rapid [min
Gear stage slow [min
Gear stage rapid [min
2.9

Coolant equipment

max. pressure head [Meter]
Delivery volume [ liter / min]
max. filling capacity [ liter ]
2.10

Environmental conditions

Temperature
2.11

Operating material

Bare steel parts
2.12

Emissions

The generation of noise emitted by the drilling-milling machine is 80 dB(A).
If the drilling-milling machine is installed in an area where various machines are in operation,
the noise exposure (immission) on the operator of the drilling-milling machine at the working
place may exceed 80 dB(A).
INFORMATION
This numerical value was measured on a new machine under the operating conditions specified
by the manufacturer. The noise behaviour of the machine might change depending on the age
and wear of the machine.
Furthermore, the noise emission also depends on production engineering factors, e.g. speed,
material and clamping conditions.
INFORMATION
The specified numerical value represents the emission level and does not necessarily a safe
working level.
EN
MB4P ǀ MB4PV
78
-1
] ~ 50 Hz
-1
] ~ 50 Hz
-1
] ~ 60 Hz
-1
] ~ 60 Hz
Humidity
Gear
Translation of original instructions
495
2500
2000
2600
95 - 1600
190 - 3200
114 - 1920
228 - 3840
3
12
8.4 litres
5-35 °C
25 - 80%
Mobilgear 627, ISO VG 100
Viscosity 100 cSt at 40°C or a comparable oil
"Lubricant" on page 145
Mobilgrease OGL 007 or,
Mobilux EP 004, acid-free oil, e.g. weapon oil, motor oil
60 - 500 infinitely variable
340 - 2760 infinitely varia-
ble
60 - 500 infinitely variable
340 - 2760 infinitely varia-
ble
Version 1.1.8 - 2021-7-29

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Opti mill mb 4pv333846033384653338466

Inhaltsverzeichnis