Installation
4
Elektrische Installation
4.4.13

Information regarding UL

Ambient Temperature
Thermal motor protection
Parameter
Functional principle
Branch Circuit Protection
36
Betriebsanleitung – MOVITRAC
HINWEIS
Das folgende Kapitel wird unabhängig von der Sprache dieser Dokumentation auf-
grund von UL-Anforderungen immer in englischer Sprache abgedruckt.
The units in IP20 are suitable for an ambient temperature of 50 °C, max. 60 °C.
The units in IP55/IP66 are suitable for an ambient temperature of 40 °C, max 50 °C.
Thermal motor overload protection shall be provided by one of the following means:
NEC compliant installation of a motor temperature sensor, see also section "Motor
temperature protection (TF/TH)" in the chapter "Electrical Installation" of the opera-
ting instructions.
Using internal thermal motor overload protection according to NEC (National Elec-
trical Code, US). Thermal motor overload protection can be activated via parame-
ter P4-17.
Implementing external measures to ensure thermal motor overload protection
according to NEC (National Electrical Code).
The following parameter must be set to enable the internal thermal motor protection
according to NEC:
P4-17 Thermal motor protection according to NEC
– 0: disabled
– 1: enabled
The motor current is accumulated in an internal memory over the course of time. The
inverter goes to fault state as soon as the thermal limit is exceeded (I.t-trP).
Once the output current of the inverter is less than the set rated motor current, the in-
ternal memory is decremented depending on the output current.
When P4-17 is disabled, thermal memory retention is reset upon shutdown or
power loss.
When P4-17 is enabled, thermal memory retention is maintained upon shutdown
or power loss.
Devices
Fuses or MCB (type B)
0008
0015
0022
®
LTP-B
1 × 200 – 240 V devices
Max. supply short cir-
cuit current
15 A
17.5 A
100 kA rms (AC)
25 A
Max. line voltage
240 V