i
What to do if... ?
...the motor fails to start?
Possible cause:
◆ Mains power not available.
Solution:
◆ Check the power with a meter to ensure that the supply voltage (230 V/50 Hz)
is available and check the wiring.
◆ Observe especially the information relating to impermissible connection types.
...The tubular motor stops after a short period of time during the
configuration and test procedures?
Possible cause:
◆ The adapter (10) may have slipped off of the limit ring (19) on the drive head (12).
Solution:
◆ Check that the adapter (10) sits flush with the drive head (12) and is fully inserted
into the rotating union (5).
◆ Slide the adapter (10) back so that it is flush with the drive head (12) and slide
the rotating union (5) fully onto the adapter (10), see Figure . Re-adjust the end
points if necessary, see page 59.
...Automatic adjustment of the lower end point does not work.
Possible cause:
◆ The catch (8) is mounted without the freewheel mechanism.
Solution:
◆ Configure the lower end point manually (see pages 63 and 64).
i
Technical specifications RolloTube X-line
Motor series
Type:
66
Medium
15/16Z
25/16Z
35/16Z
45/12Z
15
25
35
45
16
16
16
16
230
230
230
230
50
50
50
50
145
191
198
205
0.64
0.83
0.86
0.89
4
4
4
4
4
4
4
4
0.75
0.75
0.75
0.75
3
3
3
3
32
32
32
32
H
H
H
H
I
I
I
I
IP 44
IP 44
IP 44
IP 44
PVC
PVC
PVC
PVC
487
546
546
546
45
45
45
45
≤ 70
≤ 70
≤ 70
≤ 70
...The tubular motor stops between the two end points during normal
operation?
Possible cause 1:
◆ The bearing capsule (4) may not be secured with a screw to the rotating union (5)
(see Figure ), causing the rotating union (5) to slip from the motor and the
adapter (10) to come away from the limit ring (19) on the drive head (12).
Solution 1:
◆ Check for correct fitting of the bearing capsule (4) and the adapter (10). Use a
self-locking bolt to secure the bearing capsule (4) to the rotating union (5) and
remount the motor in accordance with the information on pages 52 - 56.
Possible cause 2:
◆ The thermal protection system has triggered.
Solution 2:
◆ Wait approx. 20 minutes until the motor has cooled down.
...The roller shutters stop during upward or downward travel?
Possible cause:
◆ Iced-up roller shutters or obstacle on the guide rail.
Solution:
◆ Move the roller shutters a short distance in the respective opposite direction.
◆ Rectify iced-up roller shutters or obstacle.
Nm
Rated torque:
RPM
No-load speed:
V
Rated voltage:
Hz
Frequency:
W
Rated output:
A
Power consumption:
Min.
Cyclic duration factor (KB):
Number of wires:
mm
Core cross section:
2
m
Cable length (standard):
R
Limit switch range: (number of revolutions)
Insulation class:
Protection class:
Protection class in accordance with VDE 700:
Conduction class:
mm
Motor length without bearing:
mm
Tube diameter:
dB(A)
Noise pressure level (LpA):
EN