What to do if... ?

...the motor fails to start?
Possible cause:
◆ Mains power not available.
Solution:
◆ Check the power with a meter to ensure that the supply voltage (230 V/50 Hz)
is available and check the wiring.
◆ Observe especially the information relating to impermissible connection types.
...The tubular motor stops after a short period of time during the
configuration and test procedures?
Possible cause:
◆ The adapter (10) may have slipped off of the limit ring (19) on the drive head (12).
Solution:
◆ Check that the adapter (10) sits flush with the drive head (12) and is fully inserted
into the rotating union (5).
◆ Slide the adapter (10) back so that it is flush with the drive head (12) and slide
the rotating union (5) fully onto the adapter (10), see Figure  . Re-adjust the end
points if necessary, see page 59.
...Automatic adjustment of the lower end point does not work.
Possible cause:
◆ The catch (8) is mounted without the freewheel mechanism.
Solution:
◆ Configure the lower end point manually (see pages 63 and 64).
i

Technical specifications RolloTube X-line

Motor series
Type:
66
Medium
15/16Z
25/16Z
35/16Z
45/12Z
15
25
35
45
16
16
16
16
230
230
230
230
50
50
50
50
145
191
198
205
0.64
0.83
0.86
0.89
4
4
4
4
4
4
4
4
0.75
0.75
0.75
0.75
3
3
3
3
32
32
32
32
H
H
H
H
I
I
I
I
IP 44
IP 44
IP 44
IP 44
PVC
PVC
PVC
PVC
487
546
546
546
45
45
45
45
≤ 70
≤ 70
≤ 70
≤ 70
...The tubular motor stops between the two end points during normal
operation?
Possible cause 1:
◆ The bearing capsule (4) may not be secured with a screw to the rotating union (5)
(see Figure ), causing the rotating union (5) to slip from the motor and the
adapter (10) to come away from the limit ring (19) on the drive head (12).
Solution 1:
◆ Check for correct fitting of the bearing capsule (4) and the adapter (10). Use a
self-locking bolt to secure the bearing capsule (4) to the rotating union (5) and
remount the motor in accordance with the information on pages 52 - 56.
Possible cause 2:
◆ The thermal protection system has triggered.
Solution 2:
◆ Wait approx. 20 minutes until the motor has cooled down.
...The roller shutters stop during upward or downward travel?
Possible cause:
◆ Iced-up roller shutters or obstacle on the guide rail.
Solution:
◆ Move the roller shutters a short distance in the respective opposite direction.
◆ Rectify iced-up roller shutters or obstacle.
Nm
Rated torque:
RPM
No-load speed:
V
Rated voltage:
Hz
Frequency:
W
Rated output:
A
Power consumption:
Min.
Cyclic duration factor (KB):
Number of wires:
mm
Core cross section:
2
m
Cable length (standard):
R
Limit switch range: (number of revolutions)
Insulation class:
Protection class:
Protection class in accordance with VDE 700:
Conduction class:
mm
Motor length without bearing:
mm
Tube diameter:
dB(A)
Noise pressure level (LpA):
EN

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis