Configuring tubular motors

The tubular motors can be individually configured with the help of a cord circuit setting
unit (23).
The following configurations are possible.
◆ Reload the factory settings.

Loading factory settings during the commissioning process

Automatic end point configuration is available again once the factory settings have
been loaded.
NOTE
We recommend undertaking these settings with two persons.
IMPORTANT
The tubular motor must previously have been disconnected from the
power.
1.
2.
A.
3.
4.
5.
Symbols and actions when connecting a cord circuit setting unit (23).
or
when connecting an external switch.
Switch off the mains power.
or
If a cord circuit setting unit (23) is being used, then the rocker switch must be positioned to the centre position.
OFF
B.
First press and hold the set button (11) on the tubular motor and subsequently press and hold the SET button on
the cord circuit setting device (23) (possibly a second person carries this out).
or
SET
+
Additionally switch on the mains power. Hold all buttons.
or
ON
After approx. 10 seconds the tubular motor acknowledges loading of the factory settings by briefly running up
10 s
and down.
Release the set button (11) on the tubular motor and the SET button (or the external switch, if connected).
or
SET
Switch off the mains power again.
or
OFF
NOTE
Further settings can be undertaken with the help of the optionally available RT ConfigTool.
Please refer to the information on our Website in relation to this (www.rademacher.de).
Factory settings:
End points:
Automatic adjustment of the end points:
Reversing after obstacle detection:
Reversing after blockage detection:
Shutter length compensation system:
* Please refer to the configuration options in the "Roller shutter drive" menu on page 71
and the "Awning drive" menu on page 79.
EN
No end points stored
activated
activated *
activated
activated *
65