What to do if... ?

...the motor fails to start?
Possible cause:
◆ The mains voltage is not available.
Solution:
◆ Check the power with a meter to ensure that the supply voltage (230 V) is available
and check the wiring.
◆ Observe especially the information relating to impermissible connection types.
...The tubular motor stops after a short period of time during the
configuration and test procedures?
Possible cause:
◆ The adapter (10) may have slipped off of the limit ring (18) on the drive head (12).
Solution:
◆ Check that the adapter (10) sits flush with the drive head (12) and is fully inserted
into the rotating union (5).
◆ Slide the adapter (10) back so that it is flush with the drive head (12) and slide the
rotating union (5) fully onto the adapter (10), see Fig.
if necessary, see page 43.
...Automatic adjustment of the lower end point does not work.
Possible cause:
◆ The catch (8) is mounted without the freewheel mechanism.
Solution:
◆ Configure the lower end point manually (see pages 47 and 48).
50
50
. Re-adjust the end points
...The tubular motor stops between the two end points during normal
operation?
Possible cause 1:
◆ The bearing capsule (4) may not be secured with a screw to the rotating union (5)
(see Fig.
), causing the rotating union (5) to slip from the motor and the adapter
(10) to come away from the limit ring (18) on the drive head (12).
Solution 1:
◆ Check for correct fitting of the bearing capsule (4) and the adapter (10). Use a
self-locking bolt to secure the bearing capsule (4) to the rotating union (5) and
remount the motor in accordance with the information on pages 36 - 40.
Possible cause 2:
◆ The thermal protection system has triggered.
Solution 2:
◆ Wait approx. 20 minutes until the motor has cooled down.
...The roller shutters stop during upward or downward travel?
Possible cause:
◆ Iced-up roller shutters or obstacle on the guide rail.
Solution:
◆ Move the roller shutters a short distance in the respective opposite direction.
◆ Rectify iced-up roller shutters or obstacle.