Start-Up
6.1

Capacitor forming

6-6
The DC link capacitors must be re-formed if the converter has been
non-operational for more than one year. If the converter was started-up
within one year after having been shipped (serial number on the rating
plate), it is not necessary to re-form the DC link capacitors.
Forming is realized by switching-in a rectifier and resistor, which is
connected to the DC link. The converter supply must be
disconnected (circuit: refer to Fig. 6-5)!
The forming period required depends on how long the braking unit has
been non-operational (see Fig. 6-6).