Paramete
Value
r
signal contact no.
P-1
no signal-contact monitor ring-redundancy
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor ring-redundancy
81.1.8
signal-contact monitor power-supply
Sets the monitoring of the power supply(s).
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor power-supply <P-2>
Paramete
Value
r
signal contact no.
P-1
1..2
P-2
no signal-contact monitor power-supply
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor power-supply <P-2>
81.1.9
signal-contact state
Configure the Signal Contact manual state (only takes\nimmediate effect in manual mode).
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> state <P-2>
Paramete
Value
r
signal contact no.
P-1
open
P-2
close
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016
Meaning
Meaning
Number of power supply.
Meaning
Open the signal contact (only takes effect\nin the manual mode).
Close the signal contact (only takes effect\nin the manual
mode).
Signal Contact
81.1 signal-contact
727