Herunterladen Inhalt Inhalt Diese Seite drucken

Port-Monitor Condition Overload-Detection Unit - Hirschmann Automation GRS1040 Bedienungsanleitung - Referenz-Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Port Monitor
68.2 port-monitor
68.2.9

port-monitor condition overload-detection unit

Configure Overload detection condition threshold type.
Mode: Interface Range Mode
Privilege Level: Operator
Format: port-monitor condition overload-detection unit <P-1>
Paramete
Value
r
pps
P-1
kbps
68.2.10 port-monitor condition overload-detection upper-
threshold
Configure Overload detection condition threshold type upper-threshold.
Mode: Interface Range Mode
Privilege Level: Operator
Format: port-monitor condition overload-detection upper-threshold <P-1>
Paramete
Value
r
0..10000000
P-1
68.2.11 port-monitor condition overload-detection lower-
threshold
Configure Overload detection condition threshold type lower-threshold.
Mode: Interface Range Mode
Privilege Level: Operator
Format: port-monitor condition overload-detection lower-threshold <P-1>
Paramete
Value
r
0..10000000
P-1
630
Meaning
Packets per second.
Kilobits per second.
Meaning
Enter a number in the given range.
Meaning
Enter a number in the given range.
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis