Herunterladen Inhalt Inhalt Diese Seite drucken

Hirschmann Automation GRS1040 Bedienungsanleitung - Referenz-Handbuch Seite 1072

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

54.1.21 logging email severity non-urgent
Non-urgent severity level
Mode: Global Config Mode
Privilege Level: Administrator
Format: logging email severity non-urgent <P-1>
Paramete
Value
r
emergency
P-1
alert
critical
error
warning
notice
informational
debug
0
1
2
3
4
5
6
7
54.1.22 logging email to-addr add
Create a destination address entry with default values
Mode: Global Config Mode
Privilege Level: Administrator
Format: logging email to-addr add <P-1> [addr <P-2>] [msgtype <P-3>]
[addr]: Create an entry with specified address
[msgtype]: Create an entry with specified message type
Paramete
Value
r
1..10
P-1
string
P-2
urgent
P-3
non-urgent
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016
Meaning
System is unusable. System failure has occurred.
Action must be taken immediately. Unrecoverable failure of a
component. System failure likely.
Recoverable failure of a component that may lead to system
failure.
Error conditions. Recoverable failure of a component.
Minor failure, e.g. misconfiguration of a component.
Normal but significant conditions.
Informational messages.
Debug-level messages.
Same as emergency
Same as alert
Same as critical
Same as error
Same as warning
Same as notice
Same as informational
Same as debug
Meaning
Destination address entry index
Enter a valid email address
Urgent message type
Non-urgent message type
Logging
54.1 logging
515