Verfügbare Sprachen

Power Over Ethernet (PoE)
67.2 inlinepower
67.2.6
inlinepower name
Configure the interface-related inline power interface name.
Mode: Interface Range Mode
Privilege Level: Operator
Format: inlinepower name <P-1>
Paramete
Value
r
string
P-1
67.2.7
inlinepower priority
Configure the inline power priority for this interface. In case of power scarcity, inline power on interfaces
configured with the lowest priority is dropped first.
low. The highest priority is critical.
Mode: Interface Range Mode
Privilege Level: Operator
Format: inlinepower priority <P-1>
Paramete
Value
r
crit.
P-1
high
low
67.2.8
inlinepower fast-startup
Enable or disable fast startup.
Mode: Interface Range Mode
Privilege Level: Operator
Format: inlinepower fast-startup
no inlinepower fast-startup
Disable the option
Mode: Interface Range Mode
Privilege Level: Operator
Format: no inlinepower fast-startup
622
Meaning
Enter a user-defined text, max. 32 characters.
Meaning
Set this interfaces' inline power priority to critical
(highest).
Set this interfaces' inline power priority to high.
Set this interfaces' inline power priority to low. This is the
default setting.
Possible values are: critical, high or low, default:
RM CLI HiOS-3A-MR GRS1040