Signal Contact
81.1 signal-contact
81.1.5

signal-contact monitor envm-removal

Sets the monitoring of the external non-volatile memory device removal.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor envm-removal
Paramete
Value
r
signal contact no.
P-1
no signal-contact monitor envm-removal
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor envm-removal
81.1.6

signal-contact monitor temperature

Sets the monitoring of the device temperature.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor temperature
Paramete
Value
r
signal contact no.
P-1
no signal-contact monitor temperature
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor temperature
81.1.7

signal-contact monitor ring-redundancy

Sets the monitoring of the ring-redundancy.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor ring-redundancy