Herunterladen Inhalt Inhalt Diese Seite drucken

Rmon-Alarm Disable; Rmon-Alarm Delete; Rmon-Alarm Modify - Hirschmann Automation GRS1040 Bedienungsanleitung - Referenz-Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

76.1.3

rmon-alarm disable

Disable RMON alarm.
Mode: Global Config Mode
Privilege Level: Operator
Format: rmon-alarm disable <P-1>
Paramete
Value
r
1..150
P-1
76.1.4

rmon-alarm delete

Delete RMON alarm.
Mode: Global Config Mode
Privilege Level: Operator
Format: rmon-alarm delete <P-1>
Paramete
Value
r
1..150
P-1
76.1.5

rmon-alarm modify

Modify RMON alarm parameters.
Mode: Global Config Mode
Privilege Level: Operator
Format: rmon-alarm modify <P-1> [mib-variable <P-2>] [rising-threshold <P-
3>] [falling-threshold <P-4>] [interval <P-5>] [sample-type <P-6>]
[startup-alarm <P-7>] [rising-event <P-8>] [falling-event <P-9>]
[mib-variable]: Enter the alarm mib variable.
[rising-threshold]: Enter the alarm rising threshold.
[falling-threshold]: Enter the alarm falling-threshold.
[interval]: Enter the alarm interval in seconds over which the data is sampled.
[sample-type]: Enter the alarm method of sampling the selected variable.
[startup-alarm]: Enter the alarm type.
[rising-event]: Enter the alarm rising-event index.
[falling-event]: Enter the alarm falling-event index.
Paramete
Value
r
P-1
1..150
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016
Meaning
Enter an index that uniquely identifies an entry in the alarm
table.
Meaning
Enter an index that uniquely identifies an entry in the alarm
table.
Meaning
Enter an index that uniquely identifies an entry in the alarm
table.
Remote Monitoring (RMON)
76.1 rmon-alarm
699