71.2
ptp
Enable or disable the Precision Time Protocol (IEEE 1588-2008) on a port.
71.2.1

ptp v2-transparent-clock operation

Enable or disable the sending and receiving / processing of PTP synchronization messages.
Mode: Interface Range Mode
Privilege Level: Administrator
Format: ptp v2-transparent-clock operation
no ptp v2-transparent-clock operation
Disable the option
Mode: Interface Range Mode
Privilege Level: Administrator
Format: no ptp v2-transparent-clock operation
71.2.2

ptp v2-transparent-clock asymmetry

Set the asymmetry of the link connected to this interface
Mode: Interface Range Mode
Privilege Level: Administrator
Format: ptp v2-transparent-clock asymmetry <P-1>
Paramete
Value
r
-
P-1
2000000000..20000000
00
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016