Remote Monitoring (RMON)
76.1 rmon-alarm
Paramete
Value
r
string
P-2
1..2147483647
P-3
1..2147483647
P-4
1..2147483647
P-5
P-6
absoluteValue
deltaValue
P-7
risingAlarm
fallingAlarm
risingOrFallingAlarm
1..65535
P-8
1..65535
P-9
700
Meaning
Enter an object identifier of the particular variable to be
sampled, max. 32 characters.
Enter the rising threshold for the sampled statistic.
Enter the falling threshold for the sampled statistic.
Enter the interval in seconds over which the data is sampled and
compared with the rising and falling thresholds.
Variable is compared directly with the thresholds.
Variable is subtracted from the current value and the difference
compared with the thresholds.
Single rising alarm generated when the sample is greater than
or equal to the rising threshold.
Single falling alarm generated when the sample is less than or
equal to the falling threshold.
Single Rising alarm generated when the sample is greater than
or equal to risingThreshold and single falling alarm generated
when the sample is less than or equal to fallingThreshold.
Enter the index of the eventEntry that is used when a rising
threshold is crossed.
Enter the index of the eventEntry that is used when a falling
threshold is crossed.
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016