95.1.8
track modify ping
Modify the configuration of a ping tracking instance.
Mode: Global Config Mode
Privilege Level: Operator
Format: track modify ping <P-1> [interface <P-2>] [address <P-3>] [interval
<P-4>] [miss <P-5>] [success <P-6>] [timeout <P-7>] [ttl <P-8>]
[interface]: Set the source interface number of the ping tracking instance.
[address]: Set the address of the router to be monitored.
[interval]: Set the number of milliseconds between the pings to the target router address.
[miss]: Set the number of consecutive ping misses until the tracked object is considered to be down.
[success]: Set the of consecutive ping successes until the tracked object is considered to be up.
[timeout]: Set the timeout in milliseconds for a ping reply.
[ttl]: Set the time to live for a ping request packet.
Paramete
Value
r
P-1
slot no./port no.
slot no./port no.
P-2
a.b.c.d
P-3
100..20000
P-4
1..10
P-5
1..10
P-6
10..10000
P-7
1..255
P-8
95.1.9
track modify logical
Modify the configuration of a logical tracking instance.
Mode: Global Config Mode
Privilege Level: Operator
Format: track modify logical <P-1> <P-2> <P-3> <P-4>
Paramete
Value
r
slot no./port no.
P-1
string
P-2
and
P-3
or
string
P-4
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016
Meaning
IP address.
value for ping tracking interval that could be between 100 and
20000.
value for ping tracking that could be between 1 and 10.
value for ping tracking that could be between 1 and 10.
value for ping tracking time that could be between 10 and 10000.
Enter a number in the given range.
Meaning
Track instance.
AND operator
OR operator
Track instance.
Tracking
95.1 track