81.1.3
signal-contact monitor module-removal
Sets the monitoring of the module removal.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor module-removal
Paramete
Value
r
signal contact no.
P-1
no signal-contact monitor module-removal
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor module-removal
81.1.4
signal-contact monitor envm-not-in-sync
Sets the monitoring whether the external non-volatile memory device\nis in sync with the running
configuration.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor envm-not-in-sync
Paramete
Value
r
signal contact no.
P-1
no signal-contact monitor envm-not-in-sync
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor envm-not-in-sync
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016
Meaning
Meaning
Signal Contact
81.1 signal-contact